Appliance tripping the electrics? How to find the culprit
Kettle, washing machine, dishwasher or dryer: a five-minute test to find what's tripping, and when it's the wiring instead.

Kettle, washing machine, dishwasher or tumble dryer tripping the electrics? Nine times out of ten it’s the appliance, not the wiring. Here’s how to tell.
Find the culprit in five minutes
- Unplug everything on the circuit that tripped (or switch it off at its fused spur).
- Reset the trip switch.
- Plug things back in one at a time, switching each on, until it trips.
- The last thing you plugged in is your suspect. Try it on a different circuit: if it trips there too, it’s the appliance.
Which switch tripped?
| What tripped | What it means | Typical cause |
|---|---|---|
| RCD (test button, often one of two big switches) | Current leaking to earth | A failing heating element, water in the appliance, a damaged lead |
| Breaker (MCB) for one circuit | Too much current, or a short circuit | Too many heavy appliances at once, or a fault in one appliance |
| RCBO (one switch per circuit with a test button) | Either of the above, on that circuit only | As above |
Common culprits
- Kettle: scale and age crack the element, which leaks to earth. Usually trips at switch-on. Replace the kettle.
- Washing machine or dishwasher: a heating element breaking down trips when it starts heating, partway through the cycle. A leak inside can do the same. Needs an appliance engineer.
- Tumble dryer: element or motor faults; also lint blocking the vent overheating it.
- Oven: see oven keeps tripping the electrics.
- Fridge-freezer: often trips at night or during defrost as the defrost heater comes on.
When it isn’t the appliance
If nothing’s plugged in and it still trips, or it trips whatever you plug in, the fault is in the wiring: a damaged cable, water in a socket or joint, or a failing RCD. Older boards with one RCD covering half the house also trip more because small leakages from every appliance add up. See RCD keeps tripping and does my fuse board need replacing?
We see these faults every week. Since summer 2025 our engineers have attended more than 2,700 repair call-outs in homes and flats across Herts, Beds, Bucks and London, around 630 of them for sockets and switches and over 900 for lighting.
Questions we’re asked
Why does my kettle trip the electrics?
Usually the kettle's element has cracked or scaled up and is leaking current to earth, which trips the RCD. Try it on another circuit. If it trips there too, replace the kettle.
Why does my washing machine trip the electrics halfway through?
Most often the heating element is breaking down, so it trips when the heating starts. A leak inside the machine can do the same. Call an appliance engineer.
How do I find which appliance is tripping my electrics?
Unplug everything on that circuit, reset the switch, then plug things in one at a time until it trips. Test the suspect on a different circuit to confirm.
What if it trips with nothing plugged in?
Then the fault is in the wiring or the fuse board, not an appliance. Leave it off and call an electrician to test it.
Can lots of appliances together trip an RCD?
Yes. Every appliance leaks a tiny amount to earth. On an older board where one RCD covers many circuits, those small leakages can add up and trip it. RCBOs on each circuit stop this.
Written by SEGplc. Last updated 1 November 2026.
Need it done by a date?