Appliance tripping the electrics? How to find the culprit

Kettle, washing machine, dishwasher or dryer: a five-minute test to find what's tripping, and when it's the wiring instead.

Consumer unit with RCD protection fitted by SEGplc

Kettle, washing machine, dishwasher or tumble dryer tripping the electrics? Nine times out of ten it’s the appliance, not the wiring. Here’s how to tell.

Find the culprit in five minutes

  1. Unplug everything on the circuit that tripped (or switch it off at its fused spur).
  2. Reset the trip switch.
  3. Plug things back in one at a time, switching each on, until it trips.
  4. The last thing you plugged in is your suspect. Try it on a different circuit: if it trips there too, it’s the appliance.

Which switch tripped?

What trippedWhat it meansTypical cause
RCD (test button, often one of two big switches)Current leaking to earthA failing heating element, water in the appliance, a damaged lead
Breaker (MCB) for one circuitToo much current, or a short circuitToo many heavy appliances at once, or a fault in one appliance
RCBO (one switch per circuit with a test button)Either of the above, on that circuit onlyAs above

Common culprits

  • Kettle: scale and age crack the element, which leaks to earth. Usually trips at switch-on. Replace the kettle.
  • Washing machine or dishwasher: a heating element breaking down trips when it starts heating, partway through the cycle. A leak inside can do the same. Needs an appliance engineer.
  • Tumble dryer: element or motor faults; also lint blocking the vent overheating it.
  • Oven: see oven keeps tripping the electrics.
  • Fridge-freezer: often trips at night or during defrost as the defrost heater comes on.

When it isn’t the appliance

If nothing’s plugged in and it still trips, or it trips whatever you plug in, the fault is in the wiring: a damaged cable, water in a socket or joint, or a failing RCD. Older boards with one RCD covering half the house also trip more because small leakages from every appliance add up. See RCD keeps tripping and does my fuse board need replacing?

Stop if you see or smell burning. Scorch marks, a hot or buzzing socket, sparks or a melted plug: switch off at the socket, unplug only if it is safe to touch, and if it is safe to reach, switch off the main switch on the fuse board. Then call us on 01727 238 999. If there is a fire or someone has had an electric shock, call 999.

We see these faults every week. Since summer 2025 our engineers have attended more than 2,700 repair call-outs in homes and flats across Herts, Beds, Bucks and London, around 630 of them for sockets and switches and over 900 for lighting.

Need an electrician in St Albans or Herts? Call 01727 238 999 or send us photos and a few details.

Questions we’re asked

Why does my kettle trip the electrics?

Usually the kettle's element has cracked or scaled up and is leaking current to earth, which trips the RCD. Try it on another circuit. If it trips there too, replace the kettle.

Why does my washing machine trip the electrics halfway through?

Most often the heating element is breaking down, so it trips when the heating starts. A leak inside the machine can do the same. Call an appliance engineer.

How do I find which appliance is tripping my electrics?

Unplug everything on that circuit, reset the switch, then plug things in one at a time until it trips. Test the suspect on a different circuit to confirm.

What if it trips with nothing plugged in?

Then the fault is in the wiring or the fuse board, not an appliance. Leave it off and call an electrician to test it.

Can lots of appliances together trip an RCD?

Yes. Every appliance leaks a tiny amount to earth. On an older board where one RCD covers many circuits, those small leakages can add up and trip it. RCBOs on each circuit stop this.

Written by SEGplc. Last updated 1 November 2026.

Need it done by a date?

Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.

Contact

Talk to SEG

Questions about a job, a certificate or a programme of works? Call the office or send a message. Head office in St Albans, serving Herts, Beds, Bucks and London.

Emailhello@segplc.comPhone01727 238 999Also on0345 3 822 833OfficeSEG House, 192 Watford Road, Chiswell Green, St Albans, Herts AL2 3EBHours7 days, 7am–10pm · call-outs every dayLeadershipMichael Simm · Russell Solts
Call nowGet a quote