Open · 7 days, 7am–10pmHead office St Albans · Herts · Beds · Bucks · London
  1. Home
  2. Projects
  3. Stevenage

Communal lighting improvements for a block of flats in Stevenage.

A new first-floor lighting circuit, an emergency lighting test key switch and tidy metal conduit, delivered for a housing improvement programme.

Communal undercroft walkway with bulkhead light and new conduit

As part of block improvement works for a council housing provider, a main contractor asked SEG to add a first-floor lighting circuit, an emergency lighting test key switch and to reroute ageing communal conduit.

At a glance
LocationStevenage (SG1)
CompletedAugust 2025
WorkCommunal and emergency lighting
PropertyLow-rise block of flats
Time on siteSurvey (Feb 2025), works (Apr 2025), testing and handover (13 Aug 2025)
SEG teamNoel, Petar and Luke
Communal undercroft walkway with bulkhead light and new conduit
Communal undercroft walkway with bulkhead light and new conduit
Landlord supply board with surge protection in the intake cupboard
Landlord supply board with surge protection in the intake cupboard
Surface cable run along the outside wall of the block
Surface cable run along the outside wall of the block
External wall light and cable run beside the passage entrance
External wall light and cable run beside the passage entrance

What we found

  • TN-S supply; FuseBox board replaced in 2023 - not to be changed
  • Push-fit conduit installed two years earlier, poorly routed
  • Redundant old containment in the walkways and bin store

What we did

  • Installed an additional lighting circuit on a new RCBO for the first floor
  • Fitted an emergency lighting key switch in the intake cupboard
  • Removed the old conduit and redundant containment
  • Ran new metal conduit in the agreed positions, including the ground-floor alley and bin store
  • Core-drilled for the first-floor circuit and made good with cement
  • Reused the existing light fittings
  • Tested the circuits (lighting and uplighter Zs 1.53 and 0.55 ohm; IR >200 megohm; RCD trip 30.8 and 34.8ms)
  • Recorded nine emergency light fittings on an Emergency Lighting Identification Sheet

Equipment used

  • Metal conduit
  • RCBO
  • Emergency lighting key switch
  • QTR/1900NW emergency bulkheads x9 (recorded)

Paperwork: Emergency Lighting Identification Sheet.

Need something similar in Stevenage? See emergency lighting, or electricians in Stevenage. Call 01727 238 999 or tell us about the job.

More recent local jobs

From SEG’s job records and engineers’ photos. Customer details are kept private.

Need it done by a date?

Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.

Contact

Talk to SEG

Questions about a job, a certificate or a programme of works? Call the office or send a message. Head office in St Albans, serving Herts, Beds, Bucks and London.

Emailhello@segplc.comPhone01727 238 999Also on0345 3 822 833OfficeSEG House, 192 Watford Road, Chiswell Green, St Albans, Herts AL2 3EBHours7 days, 7am–10pm · emergencies by arrangementLeadershipMichael Simm · Russell Solts
Call nowGet a quote