LD1 fire alarms for a sheltered housing scheme in Walthamstow.

Mains-powered, interlinked Aico smoke alarms in every flat, part of our LD1 programme for United Infrastructure across east London sheltered housing.

Galvanised steel conduit on the brick wall over an entrance at a sheltered housing scheme in Walthamstow

Part of our LD1 fire alarm programme for United Infrastructure across sheltered housing in east London. At this scheme in Walthamstow we are fitting mains-powered, interlinked Aico smoke alarms in the four flats and the guest suite. The building is older brick with solid walls, so where the cable routes run outside they go in galvanised steel conduit.

At a glance
LocationWalthamstow, Waltham Forest (E17)
CompletedOctober 2026 (in progress)
WorkLD1 fire alarm upgrade
PropertySheltered housing scheme: four flats and a guest suite
Time on siteJobs issued September 2026; installation under way October 2026
Galvanised conduit run along the brickwork over an entrance door, set out with a laser level
Galvanised conduit run along the brickwork over an entrance door, set out with a laser level
The new conduit dropping plumb down the wall beside the entrance, on the laser line
The new conduit dropping plumb down the wall beside the entrance, on the laser line
Conduit up the side of the building, with the SEG van parked on the street beyond
Conduit up the side of the building, with the SEG van parked on the street beyond

What we found

  • Solid brick walls, so the new cable routes run on the surface rather than being chased in
  • Copper pipework and older conduit already on the walls by the entrances, so the new runs had to be set out around them
  • Each flat sized by its number of bedrooms, so the alarm count is worked out flat by flat

What we did

  • Mains-powered Aico Ei3016 smoke alarms in the lounge, each bedroom and the hallway of every flat
  • A hardwired Aico Ei1529RC remote test switch in each flat, in an easy-to-reach place
  • Hardwired interlinks, so every alarm in a flat sounds together
  • Galvanised steel conduit on the outside walls, set out level and plumb with a laser line
  • Testing and commissioning to BS 5839-6:2019 Grade D1, Category LD1

Equipment used

  • Aico Ei3016 mains smoke alarms
  • Aico Ei1529RC hardwired remote test switches
  • Galvanised steel conduit and fittings

Paperwork: Fire alarm commissioning certificate (BS 5839-6); Electrical Installation or Minor Works Certificate.

More recent local jobs

From SEG’s job records and engineers’ photos. Customer details are kept private.

Need it done by a date?

Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.

Contact

Talk to SEG

Questions about a job, a certificate or a programme of works? Call the office or send a message. Head office in St Albans, serving Herts, Beds, Bucks and London.

Emailhello@segplc.comPhone01727 238 999Also on0345 3 822 833OfficeSEG House, 192 Watford Road, Chiswell Green, St Albans, Herts AL2 3EBHours7 days, 7am–10pm · emergencies by arrangementLeadershipMichael Simm · Russell Solts
Call nowGet a quote