Low voltage or mains garden lighting?

Most good garden schemes use both. Here is how they differ and where each one belongs.

Mature trees uplit at night

← All garden and exterior lighting

Path light among ferns, Radlett
Garden and terrace of a new-build house
Mature trees uplit at night

Side by side

Low voltage (12V or 24V)Mains (230V)
How it worksA transformer or driver steps the mains downFittings run straight from the circuit
Best forSpike lights, uplighters in beds, deck and step lightsWall lights, bollards, floodlights, long runs
Moving lights laterEasy: the cable is lighter and less hazardous if nickedHarder: armoured cable or duct, fixed positions
Long distancesVoltage drop: lights at the end can be dimmerNo problem over normal garden distances
What you needA driver somewhere dry and reachableArmoured or ducted cable, RCD protection

Why most gardens use both

A typical scheme runs a mains circuit out to a few points in the garden, then uses low voltage drivers at those points to feed spike lights and uplighters in the planting. Wall lights and bollards stay mains. That gives you movable lights where the garden changes and robust wiring where it does not.

What about solar?

Solar lights are fine for decoration, but in winter, when you most need garden lighting, they are dim and short-lived. Wired lighting works every night of the year.

Does it need certifying?

A new outdoor circuit is notifiable under Part P in England, whichever system it feeds. Plug-in low voltage kits on an existing outdoor socket are not, but the socket must be RCD protected.

Planning outdoor lighting or power? Send us a few photos, a sketch or your garden designer’s plan to tailor my quote, or call 01727 238 999. We will suggest a layout and give you a clear written price.

Photographs: a private residence in Totteridge (a project led by our director Michael Simm and now maintained by SEGplc), our garden lighting repair in Radlett and new-build houses in Radlett.

Questions we’re asked

Is low voltage garden lighting safer?

It is lower risk if a cable is cut by a spade, which is why it suits borders. The mains side, the transformer and its circuit, still needs to be installed properly.

Why are the lights at the end of my run dimmer?

Voltage drop. Long low voltage runs need thicker cable or a driver nearer the lights. We size it at design stage.

Can I mix low voltage and mains?

Yes, and most good schemes do: mains to a few points, low voltage from there into the planting.

Written by SEGplc. Last updated 19 October 2026.

Need it done by a date?

Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.

Contact

Talk to SEG

Questions about a job, a certificate or a programme of works? Call the office or send a message. Head office in St Albans, serving Herts, Beds, Bucks and London.

Emailhello@segplc.comPhone01727 238 999Also on0345 3 822 833OfficeSEG House, 192 Watford Road, Chiswell Green, St Albans, Herts AL2 3EBHours7 days, 7am–10pm · emergencies by arrangementLeadershipMichael Simm · Russell Solts
Call nowGet a quote