Garden room and garden office electrics.

A garden office needs power, light, heat and a fast connection, all running reliably at the bottom of the garden. Here is what that involves.

Wall lantern on a timber garden building

← All garden and exterior lighting

Wall lantern on a timber garden building, Hertford
Outbuilding lighting, Hertford
Terrace and garden of a new-build house, Radlett
New-build houses with landscaped gardens, Radlett

What a garden room usually needs

  • A supply cable from the house, usually armoured, sized for what you will run out there, buried or in duct.
  • Its own small consumer unit in the building, with RCD protection, so you can isolate the room on its own.
  • Earthing done properly. On many homes the supply is PME, and taking that earth out to an outbuilding is not always right. Sometimes the building needs its own earth rod. We check and decide this on survey.
  • Sockets, lighting and switching, including outside lights on the building and the path to it.
  • Heating or air conditioning, which drives the cable size more than anything else.
  • Data: a data cable or fibre in its own duct in the same trench, so the office does not rely on a Wi-Fi extender. See poor Wi-Fi signal.

A garden room supply in Radlett

A recent job, finished in February 2025: a garden room at the end of a Radlett garden, with a house fuse board that was already full. Surveying the cable route with the customer took more thought than the cable itself.

Garden with a red arrow marking the cable route towards the end of the lawn, Radlett
Marking the cable route across the garden, Radlett
Side passage beside a house with a red arrow marking a cable route, Radlett
Another route we surveyed, along the side of the house
  • The board was full. The house consumer unit had no spare way, so we fitted a 63 A isolator at the incoming supply and ran a separate armoured (SWA) supply from it to the garden room, to a consumer unit fitted by others.
  • The route. Crossing the garden meant either a catenary wire overhead or lifting the patio slabs. Neither was agreed, so the cable went through the loft space and down the opposite fence line.
  • Data. An external Cat 6 data cable went out with the power, so the room has a wired connection rather than a Wi-Fi extender.
  • The earth. At the intake we tested the earth loop, found no earth link between the incoming armoured cable and the main earth terminal, fitted a new 16 mm link and re-tested to an acceptable reading.
  • The certificate. We issued an Electrical Installation Certificate for our work. It covers the isolator and the supply cable up to the garden room consumer unit; we did not test the wiring beyond that unit, which is why it matters who signs off the room’s own circuits.

Putting a garden office online as well? See data cabling, poor Wi-Fi signal and business Wi-Fi.

Certification

A new circuit to an outbuilding is notifiable under Part P in England. We test it, issue the Electrical Installation Certificate and notify it, which you will need if you sell the house.

Plan it before the room arrives

If the base is not down yet, lay the duct now. Garden room suppliers often offer to “connect the power”; check who is signing off the work. See why to hire your own electrician.

Planning outdoor lighting or power? Send us a few photos, a sketch or your garden designer’s plan to bespoke my quote, or call 01727 238 999. We will suggest a layout and give you a clear written price.

Photographs: new-build houses in Radlett, an outbuilding in Hertford and a garden room supply job in Radlett.

Outdoor socket not working? RCD, rain and repairs

Questions we’re asked

What size cable does a garden office need?

It depends on the load and the distance. Lights, sockets and a laptop need far less than electric heating, air conditioning or a hot tub on the same supply. We calculate it on survey.

Do I need a separate fuse board in the garden room?

Usually, yes. A small consumer unit in the building lets you protect and isolate its circuits locally.

Can you run internet to the garden office?

Yes. A data cable or fibre in its own duct, laid in the same trench as the power, gives a reliable wired connection. Where a trench is not possible, we have taken the cable through the loft and along a fence line instead.

My fuse board is full. Can the garden room still have power?

Usually, yes. We can fit an isolator at the incoming supply and run a separate armoured cable to the garden room, so the house board does not need a spare way. We check the supply and earthing on survey.

Written by SEGplc. Last updated 19 October 2026.

Need it done by a date?

Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.

Contact

Talk to SEG

Questions about a job, a certificate or a programme of works? Call the office or send a message. Head office in St Albans, serving Herts, Beds, Bucks and London.

Emailhello@segplc.comPhone01727 238 999Also on0345 3 822 833OfficeSEG House, 192 Watford Road, Chiswell Green, St Albans, Herts AL2 3EBHours7 days, 7am–10pm · call-outs every dayLeadershipMichael Simm · Russell Solts
Call nowGet a quote