A ground-mounted solar array back online in Bricket Wood.
A 32-panel SolarEdge system stopped generating after a power cut. We traced the fault with SolarEdge support and had it producing again the same day.

A ground-mounted solar PV system stopped generating after a power outage. The client asked SEG to diagnose the fault and get the system running safely again.
At a glance
| Location | Bricket Wood (AL2) |
|---|---|
| Completed | April 2026 |
| Work | Solar PV repair |
| Property | Rural property with a ground-mounted array |
| Time on site | One visit (10 Apr 2026) |
| SEG team | Jamie |





What we found
- SolarEdge inverter showing a fault code after the outage
- 32 JA Solar panels in two strings of 16 on ground-mounted frames, with SolarEdge optimisers
What we did
- Inspected the array, optimisers, inverter and AC/DC isolators
- Worked with SolarEdge technical support, who accessed the inverter remotely
- Completed a firmware upgrade on the inverter
- Rebooted the system and confirmed it back in production
- Verified generation at 4.4kW on the inverter
- Confirmed panels complete and working before leaving
Equipment used
- SolarEdge inverter
- SolarEdge power optimisers
- JA Solar panels x32
- IMO DC isolator
Need something similar in Bricket Wood? See solar PV, or electricians in Bricket Wood. Call 0345 3 822 833 or tell us about the job.
More recent local jobs
- Failed loft extractor fan replaced on a same-day call-out, St Albans, October 2026
- Zappi charger, new EV board with surge protection and upgraded bonding, St Albans, January 2026
- Three boards replaced and every EICR defect put right, Hertford, June 2026
- Old Wylex board swapped for all-RCBO protection, faults traced and fixed, Radlett, November 2025
From SEG’s job records and engineers’ photos. Customer details are kept private.
Re-roofing with solar panels on the roof? Solar panel removal and reinstall
Need it done by a date?
Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.