Testing turned up a partly melted connector, loose immersion terminals and a cracked spur. We fixed them on the day and issued the EICR as Satisfactory.

Consumer unit inspected and tested during the EICR

The homeowner needed an EICR. Several faults showed up during testing, and SEG fixed them on the day so the report could be issued as Satisfactory.

At a glance
LocationWatford (WD17)
CompletedNovember 2025
WorkEICR
PropertyAll-electric home
Time on siteOne day (17 Nov 2025)
SEG teamTom
Consumer unit inspected and tested during the EICR
Consumer unit inspected and tested during the EICR
Partly melted Wago connector found on the kitchen ring circuit
Partly melted Wago connector found on the kitchen ring circuit
New fused spur fitted for the fridge
New fused spur fitted for the fridge
Socket tester confirming correct wiring after the ring repair
Socket tester confirming correct wiring after the ring repair
Bathroom ceiling light and electric shower checked during testing
Bathroom ceiling light and electric shower checked during testing

What we found

  • High R1 reading on the kitchen ring - a conductor had fallen out of a Wago, overheating and partly melting it
  • Loose earth and loose terminals at the immersion heater, with basic protection exposed
  • Cracked fused spur feeding the fridge
  • Earth to load popped out in a switch
  • One unlabelled circuit; shower Type AC RCD downstream of another 30mA RCD

What we did

  • Full EICR of the installation, including storage heaters, electric shower and off-peak immersion
  • Split the kitchen ring and dropped sockets to trace the high reading
  • Replaced the melted Wago connector and retested the ring
  • Tightened and remade the immersion heater terminations
  • Replaced the damaged fridge spur
  • Re-terminated the loose earth in the switch
  • Tested all sockets and closed up all points
  • Issued the EICR as Satisfactory

Equipment used

  • Kewtech socket tester

Paperwork: EICR (Satisfactory).

Need something similar in Watford? See EICR testing, or electricians in Watford. Call 0345 3 822 833 or tell us about the job.

More recent local jobs

From SEG’s job records and engineers’ photos. Customer details are kept private.

Need it done by a date?

Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.

Contact

Talk to SEG

Questions about a job, a certificate or a programme of works? Call the office or send a message. Head office in St Albans, serving Herts, Beds, Bucks and London.

Emailhello@segplc.comPhone0345 3 822 833St Albans local line01727 238 999OfficeSEG House, 192 Watford Road, Chiswell Green, St Albans, Herts AL2 3EBHours7 days, 7am–10pm · emergencies by arrangementLeadershipMichael Simm · Russell Solts
Call nowGet a quote