Heating controls fault near Rickmansworth.

The boiler and radiators were fine, but the heating would not start reliably. We found the fault in the controls.

Heating boost button and fused spur in a boiler room near Rickmansworth

The heating at a rural property near Rickmansworth would sometimes not come on, and a plumber had already checked the boiler and radiators. The plumber thought the fault was electrical, so we were called to check the boost button, the fused supply and the controls. We found out where the problem was in a single morning visit.

The call

The boost button in the boiler room was intermittently unresponsive, and sometimes the heating did not switch on at all. A plumber had bled the radiators, checked the flow and confirmed that the heating circuit itself was working. On his last visit the heating only restarted after the system was switched off, the fuse checked and the power switched back on, so he believed what was left was an electrical fault. The property owner asked us to inspect the boost button, the smart switch, the fused supply and the heating controls, and say whether a replacement control, timer or thermostat was needed.

What we found

Our engineer arrived just before 8 on the morning of 22 October and worked through the controls in order:

  • The symptom: the switch was coming on and off by itself.
  • The fused connection unit (FCU): checked and fine. All connections were good and the supply into it was present.
  • The circuit: the heating shares a circuit with the office power and the fire alarm. That matters when you isolate it to test, because switching it off takes more than the heating with it.
  • The boost button: removed from the wall. Power was proven live at the button with a voltage tester, so the supply to it was sound.
  • The verdict: the button itself was faulty and had to be ordered. The engineer also noted a possible problem with the Wi-Fi connection: these heating controls run from an app, so a router that has been moved or has dropped off the network can stop them responding. The position of the old Wi-Fi router was recorded for the owner.

The work, in photos

Boiler room wall with the boiler, pipework and heating controls on brickwork
The boiler room
Wall-mounted heating boost button beside a metal-clad fused connection unit
The boost button and fused spur
Consumer unit with circuits labelled by hand, including the heating circuit
The consumer unit
Boost button removed from the wall showing its wiring and the back box
Button off the wall, wiring checked
Voltage indicator used to prove power at the boost button terminals
Proving power at the button
Smart switch held in a hand showing its label and QR code
The smart switch

Photos taken on site, 22 October 2026.

The result

The supply, the fused connection unit and the wiring were all cleared in under two and a half hours, so the owner was not left paying to replace parts that were working. The fault was narrowed to the boost button, with a Wi-Fi problem as a second possibility. The call-out was quoted at an hourly rate, with any materials billed separately, so the cost followed the time the diagnosis took.

When heating faults are electrical

A boiler that works but heating that will not start is often a controls or supply problem rather than a gas or plumbing one. The usual suspects are the programmer or timer, the thermostat, a smart switch or boost button, the fused spur that feeds them, and the wiring between them. If a plumber or heating engineer has cleared the boiler and radiators, it is worth having an electrician check the rest. Boiler work itself needs a Gas Safe engineer. Controls, supplies and wiring are ours. See emergency electrician call-outs and electrical maintenance contracts for buildings with heating, hot water and fire alarm systems to look after.

Heating not coming on and the boiler is fine? Call 01727 238 999 or tell us what is happening. We cover Rickmansworth, Watford, St Albans and the rest of Hertfordshire.

Questions we’re asked

My heating will not come on but the boiler works. Who do I call?

If a heating engineer or plumber has cleared the boiler and radiators, call an electrician to check the controls: the programmer, thermostat, any smart switch or boost button, the fused spur and the wiring. Gas and boiler faults need a Gas Safe engineer.

Can a smart heating control stop working if the Wi-Fi goes down?

Yes. Controls that run from an app need the router. If the router has been moved, replaced or has lost its connection, they can stop responding. On this job our engineer recorded the old router position for that reason.

Can an electrician repair or replace a boost button, timer or thermostat?

Yes. We test the supply to the control, test the control itself, and replace it if it is faulty. We do not work on the boiler or gas side.

Why did the heating only come back after the power was switched off and on?

A control that behaves normally after a power cycle but then fails again is a typical sign of a faulty control or a loose connection. It needs testing rather than resetting, because it will come back.

Do you work near Rickmansworth?

Yes. This job was near Rickmansworth. We also cover Watford, Chorleywood, Croxley Green, St Albans and the rest of Hertfordshire, Buckinghamshire, Bedfordshire and London.

Written by SEGplc. Last updated 2 November 2026.

Need it done by a date?

Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.

Contact

Talk to SEG

Questions about a job, a certificate or a programme of works? Call the office or send a message. Head office in St Albans, serving Herts, Beds, Bucks and London.

Emailhello@segplc.comPhone01727 238 999Also on0345 3 822 833OfficeSEG House, 192 Watford Road, Chiswell Green, St Albans, Herts AL2 3EBHours7 days, 7am–10pm · call-outs every dayLeadershipMichael Simm · Russell Solts
Call nowGet a quote