Open · 7 days, 7am–10pmHead office St Albans · Herts · Beds · Bucks · London
  1. Home
  2. Tennis court lighting

Tennis court and club floodlighting.

LED lighting for tennis courts: the LTA light levels, BELL Lighting products and projects, and what the electrical work involves.

LED floodlights fitted by SEG on a column
Where the numbers come from. BELL Lighting is a UK lighting manufacturer. What this page says about BELL products and BELL projects is taken from BELL’s own published material, checked in November 2026, and linked so you can read it. The BELL projects are BELL’s, not ours. Standards and funding come from the governing bodies, linked in the text. Funding rules change often, so check before you rely on one.

Why tennis clubs are moving to LED

The Lawn Tennis Association’s guidance puts the running cost of LED courts at about £1 an hour per court, and BELL reports energy savings of more than 60 per cent against metal halide at a tennis club it lit (see below). Older floodlights also drift out of alignment in wind, which creates glare for players and neighbours. LED gives instant on and off, so lights are on only when courts are in use. Sources: the LTA Floodlighting Guidance Note (2026) and BELL’s case studies.

How much light does a court need?

The LTA sets two zones: the playing area inside the doubles lines (PPA) and the total playing area including the run-backs and side-runs (TPA).

LTA levelInside the lines (PPA)Whole court (TPA)
Recommended500 lux, evenness 0.7400 lux, evenness 0.6
Minimum400 lux, evenness 0.7300 lux, evenness 0.6

The LTA also sets a minimum maintenance factor of 0.9 for LED. Within about 30 metres of homes it advises taking specialist design advice, including modelling of light reaching nearby windows. Columns more than 20 years old need a structural check before they are reused.

BELL products for tennis courts

  • Skyline Virtus. BELL’s tennis floodlight, available with an asymmetric optic that BELL says is suited to areas needing low light pollution. IP66 and IK08, and BELL’s tennis case studies state a 50,000-hour life. A colour-temperature switchable version (3000K, 4000K and 5000K) is also listed, with an 8-year warranty quoted in BELL’s guide.
  • Skyline Padel for indoor halls. In one project BELL used it for a tennis hall (below).

BELL’s Sports Lighting Guide says six LED floodlights per court generally suit a Class 2 standard when tilted and aimed correctly, and shows an LTA design reaching 454 lux inside the lines with four fittings on four 10 m columns. Those are BELL’s own design figures; your court may differ.

BELL tennis projects

These are BELL projects elsewhere in the UK, not ours.

  • Stoney Stanton Lawn Tennis Club: 28 Virtus floodlights across three courts, replacing 36 × 400 W metal halide. BELL reports more than 400 lux inside the lines and more than 300 lux over the whole court, to the ILP’s 2021 obtrusive light guidance.
  • Boston Spa Lawn Tennis Club: Virtus on three courts. BELL reports more than 60 per cent less energy than metal halide, and says the old lights moving in high winds, which caused glare, has stopped.
  • Newlands LTC tennis hall: Skyline Padel fittings, ten per court, replacing 40 fluorescent tubes per court. BELL reports a 68 per cent fall in energy per court with roughly double the light.

More at belllighting.co.uk/resources/case-studies.

How an upgrade runs

  1. Design first. You tell us the sport, the level of play, the pitch size and the existing columns. BELL’s lighting design service, which BELL describes as complimentary, turns that into a report with a luminaire schedule and spill and glare calculations, in 3 to 5 working days for a standard project and 5 to 7 for a larger one (BELL’s figures). See BELL’s lighting design service.
  2. Survey. We look at the supply, the cable routes, the feeder pillar or switchgear, and the columns. Old columns need a structural check before new heads go on.
  3. Quote. We price the electrical works. Who does column and groundworks is agreed at survey, so you get one clear scope.
  4. Planning, if needed. The design report is what the council asks to see.
  5. Install, test and certify. Fixing, cabling, controls, electrical test certificates, then an illuminance check against the design.

What we do on the electrical side

  • Supply and capacity. We check the incoming supply early. A new or upgraded supply can add a lot to the cost, so you want to know before you commit.
  • Cabling and distribution. Armoured cable in ducts or trenches, a feeder pillar or distribution board near the pitch, and earthing for every column. The FA’s guide asks for trenches at least 450 mm deep and earth rods on all columns.
  • Protection and controls. Circuit protection sized for the load, plus the switching you want: zones, timers, dimming, or app control.
  • Testing and paperwork. Every circuit is tested and certified to BS 7671, and you get the certificates for your insurer, your council and your league.
  • Safe working. Work at height and construction health and safety planning under CDM 2015 are part of the quote, not an afterthought.

Planning and funding

Planning. The LTA says all floodlighting in the UK needs formal consent from the local authority. A conversion that stays within an existing consent can sometimes go through as a non-material amendment, but if that is refused a new application is needed. Expect conditions on hours, light levels and spill.

Costs and funding. The LTA’s guidance figure for an LED conversion is £7,000 to £8,000 per court, and it recommends a sinking fund of about £600 per court a year. The LTA Facility Loan Scheme offers loans, not grants: fixed at 5 per cent, with a possible reduction in some areas. You need to be a constituted not-for-profit with security of tenure, a sustainability plan and a sinking fund, and you register with the LTA when the project completes. Check the current terms before you apply.

Thinking about LED floodlights for your club?

Tell us the sport, the level of play and how the ground is lit now, and we will come back with what is involved.

Email the office

Tennis floodlighting questions

What light level do tennis courts need?

The LTA recommends 500 lux inside the doubles lines and 400 lux over the whole court, with a minimum of 400 and 300 lux. The figures include an evenness requirement, so it is how the light is spread as well as how much.

Do we need planning permission to change our floodlights to LED?

Often yes. Floodlights are normally covered by planning conditions on hours, light levels and light spill, so a change usually needs the council. Some swaps that stay within the existing permission can be handled as a non-material amendment, but ask your council first. Do not order anything until you know.

How much does LED save a tennis club?

The LTA puts running cost at about £1 an hour per court. BELL reports more than 60 per cent less energy than metal halide at Boston Spa Lawn Tennis Club. Your saving depends on how many hours the courts are lit.

Can we keep our existing columns?

Often, if they pass a structural check. LED heads are heavier than the metal halide heads they replace, so the columns and fixings need a structural report, and older columns may need a strength test. BELL’s published projects include several that reused existing columns.

Is there funding for a tennis club?

The LTA Facility Loan Scheme offers loans at a fixed 5 per cent to eligible clubs, not grants. Terms and eligibility change, so check with the LTA before you plan around it.

Written by SEG. Last updated 5 November 2026.

Need it done by a date?

Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.

Contact

Talk to SEG

Questions about a job, a certificate or a programme of works? Call the office or send a message. Head office in St Albans, serving Herts, Beds, Bucks and London.

Emailhello@segplc.comPhone01727 238 999Also on0345 3 822 833OfficeSEG House, 192 Watford Road, Chiswell Green, St Albans, Herts AL2 3EBHours7 days, 7am–10pm · call-outs every dayLeadershipMichael Simm · Russell Solts
Call nowGet a quote