- Home
- Football pitch lighting
Football pitch and club floodlighting.
LED floodlights for clubs: what the FA expects, what BELL Lighting offers, and what the electrical side involves.

Why football clubs are moving to LED floodlights
Older metal halide floodlights cost more to run, need regular lamp changes and lose output as they age. The FA Guide to Floodlighting puts the energy and maintenance saving from LED at 25 to 40 per cent, and says LED holds its output far better over time (5 to 10 per cent loss, against 20 to 30 per cent for metal halide). The Football Foundation estimates around £8,000 a year saved on a full-size pitch at typical use. LED also switches on instantly, so zones can be lit only when they are needed.
How much light does a pitch need?
It depends on your league. These are the figures for grass pitches in the FA’s guide. Your county FA or league confirms which grade applies to you.
| Level | Average light on the pitch |
|---|---|
| Grade A (Step 1) | 250 lux |
| Grade B (Step 2) | 200 lux |
| Grades C to G | 120 lux for existing pitches, 200 lux for upgrades or new lighting |
| Training | 120 lux |
The guide asks for an evenness (lowest point to average) of 0.60. The FA’s 3G pitch guide gives over 200 lux for a full-size match and over 120 lux for training on artificial pitches. A good design also keeps masts clear of the goal line and watches the corners, where light levels tend to drop (BELL’s Sports Lighting Guide).
BELL products for football pitches
- Skyline Powertron. BELL’s main pitch floodlight, in 600 W, 1200 W and 1800 W versions with narrow, medium, wide and slim beam options. BELL lists up to about 289,000 lumens for the 1800 W, IP66 and IK08 protection, optional shields that cut glare and upward light, and Casambi wireless control options. BELL quotes a 10-year product warranty, a 2-year on-site warranty and 100,000 hours of life.
- Skyline Projector. A symmetric floodlight with 30 and 60 degree beams, up to 1200 W, with DALI-2 and Casambi control options, suited to smaller pitches and training areas.
- Skyline Virtus. A smaller floodlight for training areas, car parks and lighting under canopies.
BELL’s own design examples show what a good scheme can reach: 270 lux with an evenness of 0.82, against the FA’s 250 lux and 0.60 for Grade A. That is BELL’s figure for its own design, not a promise for your ground. See BELL’s sports lighting range and its Sports Lighting Guide.
BELL football projects
These are BELL projects elsewhere in the UK, not ours. They show the kind of scheme we would be wiring.
- AFC Barrow, SO Legal Stadium: 24 Powertron 1800 W floodlights on 30 m columns, plus 5 Virtus under the canopies, all with wireless control. The ground is close to housing.
- Castlebar Celtic FC: 4 Powertron 1200 W on existing 12 m columns, with shields to limit glare and spill.
- Lurgan Town FC training pitches: 8 Powertron 600 W on existing columns.
All of BELL’s case studies are at belllighting.co.uk/resources/case-studies.
How an upgrade runs
- Design first. You tell us the sport, the level of play, the pitch size and the existing columns. BELL’s lighting design service, which BELL describes as complimentary, turns that into a report with a luminaire schedule and spill and glare calculations, in 3 to 5 working days for a standard project and 5 to 7 for a larger one (BELL’s figures). See BELL’s lighting design service.
- Survey. We look at the supply, the cable routes, the feeder pillar or switchgear, and the columns. Old columns need a structural check before new heads go on.
- Quote. We price the electrical works. Who does column and groundworks is agreed at survey, so you get one clear scope.
- Planning, if needed. The design report is what the council asks to see.
- Install, test and certify. Fixing, cabling, controls, electrical test certificates, then an illuminance check against the design.
What we do on the electrical side
- Supply and capacity. We check the incoming supply early. A new or upgraded supply can add a lot to the cost, so you want to know before you commit.
- Cabling and distribution. Armoured cable in ducts or trenches, a feeder pillar or distribution board near the pitch, and earthing for every column. The FA’s guide asks for trenches at least 450 mm deep and earth rods on all columns.
- Protection and controls. Circuit protection sized for the load, plus the switching you want: zones, timers, dimming, or app control.
- Testing and paperwork. Every circuit is tested and certified to BS 7671, and you get the certificates for your insurer, your council and your league.
- Safe working. Work at height and construction health and safety planning under CDM 2015 are part of the quote, not an afterthought.
Planning and funding
Planning. The FA advises talking to the council’s planning and environmental health teams early. Conditions commonly cover hours of use, light levels and spill into nearby homes, and may limit how many floodlit matches you can play each week. Councils often ask for a lighting report using the Institution of Lighting Professionals’ guidance on obtrusive light (ILP Guidance Note 1). Check current local policy: St Albans Council adopted a new Local Plan in September 2026.
Funding. Grant routes change, so check before you commit. The Football Foundation LED Floodlight Fund is currently closed to new applications. The Premier League and FA Facilities Fund has covered fixed floodlights on artificial pitches, with match funding expected and no work to start before approval (check the current terms). Hertfordshire FA asks clubs to speak to it first, and work that has already started is unlikely to be funded.
Tell us the sport, the level of play and how the ground is lit now, and we will come back with what is involved.
Football floodlighting questions
Do I need to worry about the FA grade when choosing floodlights?
Yes. Your league and step set the light level your pitch must reach, and the FA’s guide lists them. Ask your county FA which grade applies before the design is drawn, so the lighting is designed to it.
Do we need planning permission to change our floodlights to LED?
Often yes. Floodlights are normally covered by planning conditions on hours, light levels and light spill, so a change usually needs the council. Some swaps that stay within the existing permission can be handled as a non-material amendment, but ask your council first. Do not order anything until you know.
Can we keep our existing columns?
Often, if they pass a structural check. LED heads are heavier than the metal halide heads they replace, so the columns and fixings need a structural report, and older columns may need a strength test. BELL’s published projects include several that reused existing columns.
How much will LED save us?
The FA’s floodlighting guide puts the energy and maintenance saving from LED at 25 to 40 per cent compared with metal halide, and the Football Foundation estimates about £8,000 a year on a full-size pitch at typical use. Your figure depends on your hours and tariff.
How much does LED floodlighting cost?
It depends on the number of fittings, the columns, the cable runs and the supply, so we quote each ground. BELL’s design gives the schedule of fittings; we price the electrical works around it. We do not publish a figure because grounds vary so much.
Written by SEG. Last updated 5 November 2026.
Need it done by a date?
Tell us the deadline. We’ll tell you honestly whether we can hit it — and we usually can.